聯系電話:
簡要描述:0-30V/20A直流有刷(shua)無刷(shua)電機測試電源采用(yong)微電腦控(kong)制,進(jin)口可控(kong)硅作(zuo)為功率(lv)器(qi)件,原裝富士模(mo)塊(kuai)作(zuo)為調(diao)壓(ya)(ya)穩壓(ya)(ya)器(qi)件。電壓(ya)(ya)電流值從零至額(e)定值連續可調(diao),恒(heng)壓(ya)(ya)恒(heng)流自(zi)動轉換(huan)在確(que)定范圍內任意選(xuan)擇且限(xian)制保護點,電壓(ya)(ya)、電流同(tong)時LED數碼管顯示。
0-30V/20A直流有刷無刷電機測試電源采(cai)用微電(dian)(dian)腦控制(zhi),進口可控硅作(zuo)為(wei)功率器(qi)件,原裝富士模塊作(zuo)為(wei)調壓(ya)(ya)穩壓(ya)(ya)器(qi)件。電(dian)(dian)壓(ya)(ya)電(dian)(dian)流值從零(ling)至額定值連(lian)續可調,恒壓(ya)(ya)恒流自(zi)動轉換在確(que)定范圍內(nei)任(ren)意選擇且(qie)限制(zhi)保護(hu)點,電(dian)(dian)壓(ya)(ya)、電(dian)(dian)流同時LED數碼管顯示。
0-30V/20A直流有刷無刷電機測試電源廣泛(fan)應用于(yu)各大(da)專院校實驗(yan)室、電(dian)(dian)機自動(dong)測試設備(bei)、直流有(you)刷無(wu)刷電(dian)(dian)機。在生產線上可以(yi)提供開(kai)關電(dian)(dian)源(yuan)無(wu)法達到的超大(da)電(dian)(dian)流的直流電(dian)(dian)源(yuan)。應用范圍電(dian)(dian)動(dong)車電(dian)(dian)機檢測、馬達等電(dian)(dian)子器件(jian)檢測、直流有(you)刷無(wu)刷電(dian)(dian)機,例行試驗(yan)其它一切需要使用直流電(dian)(dian)源(yuan)的場合。
特(te)點:智(zhi)能型線性直流穩壓(ya)(ya)電源(yuan)與市場上普通的繼(ji)電器(qi)調(diao)壓(ya)(ya)式和(he)調(diao)壓(ya)(ya)變壓(ya)(ya)器(qi)式直流電源(yuan)、開關(guan)直流電源(yuan)相(xiang)比,具有(you)精(jing)度高,波(bo)紋(wen)小(xiao),穩定性*的特(te)點(dian)。它(ta)具有(you)完(wan)善的保護線路,更(geng)能滿足使(shi)用者(zhe)簡單(dan)、方便的使(shi)用需求,獲(huo)得(de)用戶的高度評(ping)價。
使用(yong)說明:1、每臺設備三相電(dian)(dian)(dian)(dian)(dian)(dian)壓須經過外接(jie)空(kong)氣開關(guan)接(jie)入,接(jie)好保護(hu)(hu)接(jie)地線。2、直流(liu)輸(shu)出(chu)(chu)(chu)(chu)(chu)銅排(pai)位(wei)于電(dian)(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)后方,在連接(jie)電(dian)(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)與鍍(du)槽選(xuan)用(yong)的銅排(pai)截面每平方毫米不(bu)可(ke)超(chao)過三安培。3、開機時(shi)(shi)先閉合外控(kong)空(kong)氣開關(guan),此時(shi)(shi)LD電(dian)(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)指示(shi)燈(deng)亮(liang),電(dian)(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)電(dian)(dian)(dian)(dian)(dian)(dian)壓表數值均為(wei)零狀態;啟動(dong)遠控(kong)工(gong)作(zuo)開關(guan),工(gong)作(zuo)指示(shi)燈(deng)亮(liang);調節(jie)定(ding)壓定(ding)流(liu)旋鈕,使輸(shu)出(chu)(chu)(chu)(chu)(chu)達到(dao)所需值。4、恒(heng)定(ding)電(dian)(dian)(dian)(dian)(dian)(dian)流(liu)時(shi)(shi),電(dian)(dian)(dian)(dian)(dian)(dian)流(liu)電(dian)(dian)(dian)(dian)(dian)(dian)壓的變(bian)化(hua)(hua)或負(fu)載的變(bian)化(hua)(hua)均能保持輸(shu)出(chu)(chu)(chu)(chu)(chu)電(dian)(dian)(dian)(dian)(dian)(dian)流(liu)恒(heng)定(ding)(此方式(shi)在空(kong)載輸(shu)出(chu)(chu)(chu)(chu)(chu)不(bu)受控(kong))5、恒(heng)定(ding)電(dian)(dian)(dian)(dian)(dian)(dian)壓時(shi)(shi),電(dian)(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)電(dian)(dian)(dian)(dian)(dian)(dian)壓的變(bian)化(hua)(hua)活負(fu)載變(bian)化(hua)(hua)均能保持輸(shu)出(chu)(chu)(chu)(chu)(chu)電(dian)(dian)(dian)(dian)(dian)(dian)壓恒(heng)定(ding)6、電(dian)(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)工(gong)作(zuo)時(shi)(shi),其輸(shu)出(chu)(chu)(chu)(chu)(chu)電(dian)(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)應在額定(ding)工(gong)作(zuo)電(dian)(dian)(dian)(dian)(dian)(dian)流(liu)一下,禁止超(chao)負(fu)荷運(yun)行(xing)(xing)。佳工(gong)作(zuo)狀態為(wei)額定(ding)值的80%,選(xuan)機時(shi)(shi)需注意。7、溫度(du)(du)保護(hu)(hu),當(dang)機內溫度(du)(du)升至85℃時(shi)(shi),電(dian)(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)自(zi)(zi)動(dong)停止輸(shu)出(chu)(chu)(chu)(chu)(chu),降溫后自(zi)(zi)行(xing)(xing)啟動(dong)輸(shu)出(chu)(chu)(chu)(chu)(chu)8、輸(shu)出(chu)(chu)(chu)(chu)(chu)短路或故障,會立(li)即保護(hu)(hu)。 產品規格:1、輸(shu)出(chu)(chu)(chu)(chu)(chu)電(dian)(dian)(dian)(dian)(dian)(dian)壓:0~36V可(ke)選(xuan)(18V-36V輸(shu)出(chu)(chu)(chu)(chu)(chu)電(dian)(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)在0-5000A可(ke)選(xuan)) 輸(shu)出(chu)(chu)(chu)(chu)(chu)電(dian)(dian)(dian)(dian)(dian)(dian)流(liu):0-10000A可(ke)選(xuan)。2、特(te)殊規格可(ke)面議。